This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| electronic:equipment:sensor:faipir [2023/08/24 22:08] – [Controls] tony | electronic:equipment:sensor:faipir [2026/09/06 22:42] (current) – tony | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | < | ||
| + | < | ||
| + | \\ | ||
| + | {{ electronic: | ||
| + | ^ Sensor data || | ||
| + | ^Model|FAI/ | ||
| + | ^Manufacturer|Ness| | ||
| + | ^Board IDs|105-168, | ||
| + | ^FCCID| | | ||
| + | ^Type|PIR| | ||
| + | ^ Coverage|°| | ||
| + | ^ Range|to 15m| | ||
| + | ^Connection|Wireless, | ||
| + | ^Power|9V Lithium Battery| | ||
| + | ^Sensors|PIR| | ||
| + | ^Controls|Radio Enable, Pulse Link 1-2/3-4, Range High/Low, Test/ | ||
| + | ^Outputs| | | ||
| + | ^Date|1996| | ||
| + | |||
| + | ==== Components ==== | ||
| + | * 271C | ||
| + | * LM346M | ||
| + | * 56AB | ||
| + | * CD4093BCM | ||
| + | * NESSCODE-2 | ||
| + | |||
| + | |||
| + | ==== Controls ==== | ||
| + | * Radio enable jumper: Enable/ | ||
| + | * Test/ | ||
| + | * Test: Sensor re-triggered by every event with no idle timeout. LED flashes for every trigger. | ||
| + | * Prog: For setting a new 16bit identification code (random or fixed) for this PIR | ||
| + | * 1/0/R jumper block: | ||
| + | * Norm: Normal operation, 3 minute idle time before re-triggering to save battery life. | ||
| + | * Range high/low jumper: High sensitivity will detect up to 14m, low for up to 8m. | ||
| + | * Pulse count jumper: On for 1 to 2 movement detections to cause and alarm, off for less sensitive requiring 3 to 4 pulses. | ||
| + | * Height scale: A graduated scale from 1.1m to 4.1m marked on the circuit board, so that it can be slid up or down to maximise the range, depending on the height on the wall that the sensor is mounted. | ||
| + | |||
| + | ==== Sensors ==== | ||
| + | * PIR: Heimann LHI 958 | ||
| + | * Lenses: A front facing wide angle graduated Fresnel lens, and a 'creep under' downward facing Fresnel lens. | ||
| + | * Tamper switch: There is provision on the PCB for mounting a tamper switch, but missing from this example. | ||
| + | |||
| + | ===== Examples ===== | ||
| + | {{electronic: | ||
| + | |||
| + | | |{{electronic: | ||
| + | |{{electronic: | ||
| + | | |{{electronic: | ||
| + | |||
| + | \\ | ||
| + | ---- | ||
| + | ===== Tear down ===== | ||
| + | |||
| + | {{electronic: | ||
| + | |||
| + | {{electronic: | ||
| + | |||
| + | {{electronic: | ||
| + | |||
| + | {{electronic: | ||
| + | |||
| + | {{electronic: | ||
| + | |||
| + | {{electronic: | ||
| + | |||
| + | {{electronic: | ||
| + | |||
| + | ====== References and Additional Resources ====== | ||
| + | * | ||
| + | |||
| + | < | ||
| + | \\ | ||
| + | ---- | ||
| + | < | ||